12V DC Distro Panel β Quick Start
SB50 main feed β’ Fused Powerpole branches β’ USB-C PD 100W β’ Common negative with shunt.
Ports & Legend
- SB50 IN β from fused 12 V source
- MASTER β panel ON/OFF (breaker/toggle)
- +BUS / βBUS β internal distribution
- FUSE BLOCK β 5β30 A per branch
- POWERPOLE β keyed, check polarity labels
- USB-C PD β up to 100 W (20 V Γ 5 A)
- METER/SHUNT β volts/amps, all returns after shunt
Start / Stop
- Inspect cables & fuses; vents clear.
- Connect SB50 IN to fused source.
- Switch MASTER ON.
- Verify voltage on meter (β12.8β13.4 V LiFePOβ).
- Plug loads to Powerpoles/USB-C one at a time.
Shutdown: unplug loads β MASTER OFF β disconnect SB50.
Fuse & Wire (quick)
| Branch | Fuse | Wire |
|---|---|---|
| Router/LTE/AP | 5β10 A | 16β14 AWG |
| LED bars (2Γ) | 10β15 A | 14 AWG |
| Cooler/Comp. | 20β30 A | 12β10 AWG |
| 12 V pump | 15β20 A | 14β12 AWG |
| USB-C PD 100 W | 10 A | 14β12 AWG |
Fuse protects the wire (and device). Keep runs short; target β€3% drop.
Limits & Indicators
- Total continuous panel current: β€ 60 A
- Branch current β€ branch fuse & wire ampacity
- USB-C 100 W requires E-Marker cable
- Warm connector = poor crimp or undersized wire
If meter shows 0 A with loads: returns bypassed shunt β re-land negatives after shunt.
Wiring Snapshot
Batt + β [60β80A FUSE @ source] β SB50 IN β MASTER β +BUS β [FUSE BLOCK] β Branches
Batt β βββββββββββββββββββββββββββββββββββββββ (SHUNT) β βBUS β Branch returns
+BUS β (10A) β USB-C PD 100W | βBUS β USB-C PD return
Do Not
- No reverse polarity on SB50/Powerpoles
- No bypassing fuses or oversizing fuses past wire rating
- No AC backfeed β this panel is DC only
Emergency
- Smell/smoke/overheat β MASTER OFF
- Disconnect SB50 at source
- Let cool; inspect lugs, fuses, polarity
Full guide & specs: gamerzcrave.com/dc-panel (QR here)